GF601 Single-Axis Fluxgate Magnetometer

- Range: ±100μT  ~ ±2000μT

- DC Basic Accuracy: 0.5%

- AC Basic Accuracy: 1%

- Finest resolution: 0.1nT

- DC/AC measurement mode switch

- Frequency response: DC- 2kHz

- Transverse and axial probe optional


Download



GF601 Single-AxisFluxgate Magnetometer


Description:

The 2025-Version Three-axis Fluxgate Magnetometer GF601, madeby COLIY, has the excellent ergonomic design with the latest electronic technology, and it’s one of best choices to measure low-intensity magnetic field. This handheld fluxgate magnetometer can be used in geomagnetism detection, wrapped detection, traffic monitoring, measuring residual magnetism, low-intensity magnetic field measurement, etc.

The key feature of the 2025-Version Magnetometer GF601 is that the size of the probe is reduced to only 24x24x50mm, which is only 1/4 ofthe size of the old version, and it is one of the smallest high-performance fluxgate probes at present, which can be measured in a small space. Magnetometer GF601 adopts a high-precision 24-bit ADC chip, which greatly improves the magnetic field resolution. High performance circuit supports the measurement resolution of 0.1nT within the full measurement range. The power consumption of the whole machine is reduced by 1/4. Magnetometer GF601 boasts with an industrial class 3.2 inches touch panel display that enables customers’ instantaneous and simultaneous measurement results [Max/ Min/ Peak/ Hold/ Alarm/ Polarity, Magnetic Flux Density,and Trend Graph etc.].

Magnetometer GF601 can be used to detect DC magnetic field in DC measurement mode and AC magnetic field in AC measurement mode respectively: GF601 allows DC measurements with a basic accuracy of 0.5%, resolution of 0.1nT and AC measurement with a basic accuracy of 1% and frequency response range of DC~ 2kHz.

In addition, Magnetometer GF601 has passed the CE certification and EMC(Electromagnetic Compatibility) test.

 

Parameter Comparison

Product Version

2025-Version

2020-Version

Probe Size

24x24x50mm

32x32x107mm

Sampling ADC bits

24 bits

18 bits

Measurement Resolution

0.1nT

1nT

Frequency Response

DC - 2kHz

DC - 1kHz

Power Consumption

Reduced by 1/4

High

Max Range

2mT

1mT

Probe Cable’s Length

Up to 100m

Up to 10m

 

 

Features

l  GUI Operation System

l  3.2 inches color touch LCD

l  Full 5 display digits

l  Max/Min/Hold Function

l  Display trend graph & Alarm

l  S or N Polar indication

l  Transverse and axial probe optional

lRange: ±100μT ~ ±2000μT

l  DC Basic Accuracy: 0.5%

l  AC Basic Accuracy: 1%

l  Finest resolution: 0.1nT

l  DC/AC measurement mode switch

l  Frequency response: DC- 2kHz

lSmall-size Probe (24x24x50mm)

 

 

 

GF601 Magnetometer Specification:

Model

GF601 / GF601S

Measurement  Specification

Accuracy

DC

±0.5%  Reading± 0.1% FS

AC

±1%  Reading ± 0.1% FS  [fT ≤ 200Hz]

±2%  Reading ± 0.1% FS  [200Hz < fT  ≤ 500Hz]

±10%  Reading ± 0.1% FS [500Hz < f≤  2000Hz]

Range (FS)

±100μT

±1000μT

Finest Display Resolution

0.1nT

0.1nT

Measurement Resolution

0.1nT

0.5nT

Typical Temperature Coefficient  ppm/

±100

±200

Frequency Response [fT]

DC – 2kHz

Display Digits

5 digits (More display digits will be  shown in supporting PC software)

Hysteresis

<2nT for exposure to up to 2 x full  scale

<20nT for exposure to 10mT field  within 10s

Front Panel

Screen

3.2  inches color resistive touch LCD,320x240 Pixel

Units

Gauss(G), Tesla(T), Amperes per meter  (A/m)

Display Update Rate

3 readings/second

Display Mode

DC, AC, MAX, MIN, Trend Graph, Alarm,  Polarity Indication, etc.

Probe

Start-up Time

150 ms

Warm-up Time

15 min

Probe Range

Could be customized within ±2000μT

Probe Cable Length

Standard  1.5m; Customizable longest length of 100m.

USB Interface

Function

1,  Communication Interface: to connect PC with Magnetometer host for monitoring  the measurement;

2,  Charging interface: to connect PC or mobile power with Magnetometer host for  charging

Software/ Driver

SMART PC Software without any driver

Host Specifications

Operating Temperature

+15  to  +35(Rated Accuracy)

-10  to  +60(Reduced accuracy)

Storage Temperature

- 20°C   to  +75°C

Ambient Magnetic Field

<100G (10mT)

Battery

Rechargeable 4500mAH Li-ion

Operating Battery Life

6 hours; Can be charged by AC power or  portable battery

Dimension

238 mm W × 95 mm H × 42  mm  D

Weight

350g

Certification

CE Certification, EMC Certification

Note:

1, AC Range mentioned above refers to AC magnetic field measurement range after DC magnetic field is shielded, so if DC magnetic field is not shielded, and users want to measure magnetic field in AC measurement mode, AC Range is equivalent to the value that 0.7 times of DC Range minus DC magnetic field intensity. [SQRT(2)/2 ≈ 0.7]

 

 


Description of Magnetometer Selection

 

GF601

-A

10

Magnetometer  Model

 

GF601

Probe Type

 

-A – Axial  Probe

-T –  Transverse Probe

Measurement  Range

01 – ±100μT

02 – ±200μT

05 – ±500μT

10 – ±1000μT

15 – ±1500μT

20 – ±2000μT

 For example:


Model

Descriptions

GF601-A01

3-Axis  Fluxgate Magnetometer

l  With an Axial Fluxgate Probe (±100μT range)

GF601-A10

3-Axis  Fluxgate Magnetometer

l  With an Axial Fluxgate Probe (±1000μT range)

GF601-T01

3-Axis  Fluxgate Magnetometer

l  With a Transverse Fluxgate Probe (±100μT range)

GF601-T10

3-Axis  Fluxgate Magnetometer

l  With a Transverse Fluxgate Probe (±1000μT range)

Note:

1,Probes can be customized within ±2000μT; Unit Conversion: 1G=100μT=100,000nT;

2,The probe cable length is 1.5m default, and could be customized within 100m.

3,Fluxgate probe housing is made of POM and IP68 protection.

 

 

Optional Accessories

 

Model

Descriptions

GHOLD100

3-Direction Precision Movement  Platform, is made of non-magnetic material. Users fixed the probe on the  bracket front-end, and then manually rotate the knob so that the probe moves  stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum  strokes of XYZ axis are 180mm,180mm and 280mm, and positioning accuracy is  0.1mm; center load: 20kg; weight: 6.2kg  

SAMRT PC  Software

PC SOFTWARE for Magnetometer

Probe  Extension Cable

MAX length is 100m

    




Feedback Please submit your comments, and we will give feedback in the first time.

Title: *
Name: * E-mail:* Tel:*
Content:*
Code: 
*

COPYRIGHT ©  2024 Coliy  Group  

Support:35.com
Follow Us :