Coliy  Group

sales@coliy.com   
HOME PRODUCTS ABOUT US NEWS CONTACT
HOME PRODUCTS ABOUT US NEWS CONTACT

Home > Products > Weak magnetic field meter
GF603 3-Axis Fluxgate Magnetometer

• Range: ±100μT ~ ±1500μT

• DC Basic Accuracy: 0.25%
• Frequency response of DC- 2kHz
• S or N Polar indication
• Max/Min/Hold Function
• Display XYZ components and vector

• Small-size Probe (24x24x50mm)

• [GF603S] Real-time spectrum analysis

• Display Resultant (R), Declination (D) and Inclination (I)

Download


COLIY®--Excellent Solution for Magnetic  Field Measurement

High Magnetic Field (0-20T) Measurement

Model

Principle

Type

Axis

DC Accuracy

Range

Resolution

G80

HALL

Handheld

1

2%

2T

10μT

G81

HALL

Handheld

1

0.8%

10T

1μT

G93

HALL

Handheld

3

1%, 0.5%

20T

10μT

G401

HALL

Desktop

1

0.04%

10T

1μT

X113

HALL

Sensor

1

0.05%

15T

TC of sensitivity: 30ppm/K

Low Magnetic Field(0- 2mT) Measurement

Gaussmeters for Low Magnetic Field

Model

Principle

Type

Axis

DC Accuracy

Range

Resolution

GF601

Fluxgate

Handheld

1

0.5%

1mT

0.1nT

GF603

Fluxgate

Handheld

3

0.25%

1.5mT

0.1nT

Note: 1T= 10kG; 1mT= 10G;  1μT= 10mG;   1nT= 10μG


GF603 Three-Axis Fluxgate Magnetometer



Description: 

The 2025-Version Three-axis Fluxgate Magnetometer GF603, madeby COLIY, has the excellent ergonomic design with the latest electronictechnology, and it’s one of best choices to measure low-intensity magnetic field. This handheld fluxgate magnetometer can be used in geomagnetism detection, wrapped detection, traffic monitoring, measuring residual magnetism,low-intensity magnetic field measurement, etc.

The key feature of the 2025-Version Magnetometer GF603 is that the size of the probe is reduced to only 24x24x50mm, which is only 1/4 ofthe size of the old version, and it is one of the smallest high-performance fluxgate probes at present, which can be measured in a small space. Magnetometer GF603 adopts a high-precision 24-bit ADC chip, which greatly improves the magnetic field resolution. High performance circuit supports the measurement resolution of 0.1nT within the full measurement range. The power consumption ofthe whole machine is reduced by 1/4. Magnetometer GF603 boasts with an industrial class 3.2 inches touch panel display that enables customers’ instantaneous and simultaneous measurement results [Max/ Min/ Peak/ Hold/ Alarm/ Polarity, XYZ axis and vector of Magnetic Flux Density, Declination/Inclination (D/I), Trend Graph and Real-time Spectrum Analysis (with model GF603S) etc.].

Magnetometer GF603 can be used to detect DC magnetic field in DC measurement mode and AC magnetic field in AC measurement mode respectively: GF603 allows DC measurements with a basic accuracy of 0.25%, resolution of 0.1nT and AC measurement with a basic accuracy of 1% and frequency response range of DC~ 2kHz. Meanwhile, Magnetometer GF603S has the function of real-time spectrum analysis within the frequency range 15Hz- 2kHz.

In addition, Magnetometer GF603 has passed the CE certification and EMC (Electromagnetic Compatibility) test.


Parameter Comparison

Product Version

2025-Version

2020-Version

Probe Size

24x24x50mm

32x32x107mm

Sampling ADC bits

24 bits

18 bits

Measurement Resolution

0.1nT

1nT

Frequency Response

DC - 2kHz

DC - 1kHz

Power Consumption

Reduced by 1/4

High

Max Range

1.5mT

1mT

Probe Cable’s Length

Up to 300m

Up to 50m


Features

l  GUI Operation System

l  3.2 inches color touch LCD

l  Full 5 display digits

l  Max/Min/Hold Function

l  Display trend graph & Alarm

l  Display XYZ axis and vector

l  Display R, D, I values

l  S or N Polar indication

l  Range: ±100μT ~ ±1500μT

l  DC Basic Accuracy: 0.25%

l  AC Basic Accuracy: 1%

l  Finest resolution: 0.1nT

l  DC/AC measurement mode switch

l  Frequency response: DC- 2kHz

l  [GF603S] Real-time spectrum analysis

l  Small-size Probe (24x24x50mm)




GF603 Magnetometer Specification:

Model

GF603 / GF603S

(DC) Measurement  Specification

Tested item

X, Y, Z

Vector R

*D

*I

Range (FS)

±100μT

±1000μT

173μT

1732μT

±180°

±90°

Accuracy

±0.25%  Reading   ±0.1% FS

±0.25% Reading   ±0.1% FS

±0.5% Reading   ±0.1% FS

±0.5% Reading   ±0.1% FS

Finest Display Resolution

0.1nT

0.1nT

0.1°

0.1°

Measurement Resolution

0.1nT

0.2nT

0.1nT

0.2nT

0.1°

0.1°

Typical Temperature Coefficient  ppm/

±100

±200

±100

±200

N/A

Display Digits

5 digits (More display  digits will be shown in supporting PC software)

4 digits

Real-time Spectrum

Only GF603S within 15Hz~ 2kHz

N/A

Hysteresis

<2nT for exposure to up to 2 x full  scale

<20nT for exposure to 10mT field  within 10s

N/A

(AC) Measurement Specification

*Range

X,  Y, Z

±70μT

±700μT

R

121.2μT

1212.4μT

Accuracy

X,  Y, Z

±1%  Reading ± 0.1% FS   [fT ≤  300Hz]

±2%  Reading ± 0.1% FS   [300Hz < fT  ≤ 500Hz]

±10%  Reading ± 0.1% FS  [500Hz < f≤ 2kHz]

R

±2%  Reading ± 0.1% FS   [fT ≤  300Hz]

±4%  Reading ± 0.1% FS   [300Hz < fT  ≤ 500Hz]

±18%  Reading ± 0.1% FS  [500Hz < f≤ 2kHz]

Frequency Response [fT]

DC – 2kHz

Front Panel

Screen

3.2  inches color resistive touch LCD,320x240 Pixel

Units

Gauss(G), Tesla(T), Amperes per meter  (A/m)

Display Update Rate

3 readings/second

Display Mode

DC, AC, XYZ Axis, Vector R, Declination,  Inclination, MAX, MIN, Trend Graph, Alarm, Polarity Indication, Real-time Spectrum  [GF603S] etc.

Probe

Start-up Time

150 ms

Warm-up Time

15 min

Probe Range

Could be customized within ±1500μT

Probe Cable Length

Standard  1.5m; Customizable longest length of 300m; The probe is directly connected to  the host via cable and without plug-in.

USB Interface

Function

1,  Communication Interface: to connect PC with gaussmeter host for monitoring  the measurement;

2,  Charging interface: to connect PC or mobile power with gaussmeter host for  charging

Software/ Driver

SMART PC Software without any driver

Host Specifications

Operating Temperature

+15  to  +35(Rated Accuracy)

-10  to  +60(Reduced accuracy)

Storage Temperature

- 20°C   to  +75°C

Ambient Magnetic Field

<100G (10mT)

Battery

Rechargeable 4500mAH Li-ion

Operating Battery Life

6 hours; Can be charged by AC power or  portable battery

Dimension

238 mm W × 95 mm H × 42  mm  D

Weight

350g

Certification

CE Certification, EMC Certification

Note:

1, D- Declination, is the angle thatbetween the Z axis and the projection of the field vector onto the XZ plane.

2, I- Inclination, is the angle thatbetween the field vector and the XZ plane.

3, AC Range mentioned above refers to ACmagnetic field measurement range after DC magnetic field is shielded, so if DCmagnetic field is not shielded, and users want to measure magnetic field in ACmeasurement mode, AC Range is equivalent to the value that 0.7 times of DCRange minus DC magnetic field intensity. [SQRT(2)/2 ≈ 0.7]


Probes Specification

Model  GF603/ GF603S Magnetometer Probes

Probe Model

*Range

Frequency Response

Probe Size

Typical

Temperature 

Coefficient

DC Accuracy

( 25)

Stem Material

GFs-Y01

±100μT

DC-2kHz

 24x24x50 mm

±100ppm/

±0.25%

POM

GFs-Y02

±200μT

DC-2kHz

 24x24x50 mm

±100ppm/

±0.25%

POM

GFs-Y05

±500μT

DC-2kHz

 24x24x50 mm

±150ppm/

±0.25%

POM

GFs-Y10

±1,000μT

DC-2kHz

 24x24x50 mm

±200ppm/

±0.25%

POM

GFs-Y15

±1,500μT

DC-2kHz

 24x24x50 mm

±250ppm/

±0.25%

POM

Note:

1,Probes can be customized within ±1500μT;Unit Conversion: 1G=100μT=100,000nT;

2,The probe is connected and fixed with the host through the cable, no plug-in,non-removable, please select the appropriate range and probe cable lengthbefore ordering.

3,The probe cable length is 1.5m default, and could be customized within300m.

4,Fluxgate probe’s environmental protection / sealing is IP66 by default;

4,Please contact Coliy for probes with higher environmental protection,like supporting the fluxgate probe in the long-term work of 100meters underwater.


Optional Accessories

Model

Descriptions

GHOLD100

3-Direction Precision Movement  Platform, is made of non-magnetic material. Users fixed the probe on the  bracket front-end, and then manually rotate the knob so that the probe moves  stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum  strokes of XYZ axis are 180mm,180mm and 280mm, and positioning accuracy is  0.1mm; center load: 20kg; weight: 6.2kg  

SAMRT PC  Software

PC SOFTWARE for Magnetometer

Probe  Extension Cable

MAX length is 300m



Description of Magnetometer Host Type Selection


Magnetometer

Description

GF603

Magnetometer WITHOUT the function of real-time spectrum analysis

GF603S

Magnetometer WITH the function of real-time spectrum analysis





Feedback Please submit your comments, and we will give feedback in the first time.

Title: *
Name: * E-mail:* Tel:*
Content:*
Code: 
*

COPYRIGHT ©  2024 Coliy  Group  

Support:35.com
Follow Us :