Coliy Group
• Range: ±1G(±100μT) and ±10G(±1mT)
• DC Basic Accuracy: 0.25%
• Frequency response of DC- 1kHz
• S or N Polar indication
• Max/Min/Hold Function
• Display XYZ components and vector
• Display Resultant (R), Declination (D) and Inclination (I)
COLIY®--Excellent Solution for Magnetic Field Measurement | ||||||
High Magnetic Field (0-20T) Measurement | ||||||
Model | Principle | Type | Axis | DC Accuracy | Range | Resolution |
HALL | Handheld | 1 | 2% | 2T | 10μT | |
HALL | Handheld | 1 | 0.8% | 10T | 1μT | |
HALL | Handheld | 3 | 1%, 0.5% | 20T | 10μT | |
HALL | Desktop | 1 | 0.04% | 10T | 1μT | |
HALL | Sensor | 1 | 0.05% | 15T | TC of sensitivity: 30ppm/K | |
Low Magnetic Field(0- 2mT) Measurement | ||||||
Gaussmeters for Low Magnetic Field | ||||||
Model | Principle | Type | Axis | DC Accuracy | Range | Resolution |
Fluxgate | Handheld | 1 | 0.5% | 1mT | 0.1nT | |
Fluxgate | Handheld | 3 | 0.25% | 1mT | 0.1nT | |
Note: 1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG |
Description:
Three-axis Fluxgate Magnetometer GF603, made by COLIY, has the excellent ergonomic design with the latest electronic technology, and it’s one of best choices to measure low-intensity magnetic field. This handheld fluxgate magnetometer can be used in geomagnetism detection, wrapped detection, traffic monitoring, measuring residual magnetism, low-intensity magnetic field measurement, etc.
GF603 boasts with an industrial class 3.2 inches touch panel display that enables customers’ instantaneous and simultaneous measurement results [Max/ Min/ Peak/ Hold/ Alarm/ Polarity, XYZ axis and vector of Magnetic Flux Density, Declination/Inclination (D/I), Trend Graph and Real-time Spectrum Analysis (with model GF603S) etc.].
Magnetometer GF603 can be used to detect DC magnetic field in DC measurement mode and AC magnetic field in AC measurement mode respectively: GF603 allows DC measurements with a basic accuracy of 0.25%, resolution of 0.1nT and AC measurement with a basic accuracy of 1% and frequency response range of DC~ 1kHz. Magnetometer GF603 could be equipped with 3-Axis Probes of different range: ±100μT and ±1000μT. Meanwhile, Magnetometer GF603S has the function of real-time spectrum analysis within the frequency range 15Hz- 1kHz.
In addition, Magnetometer GF603 has passed the CE certification and EMC (Electromagnetic Compatibility) test.
Features | |
l GUI Operation System l 3.2 inches color touch LCD l Full 5 display digits l Max/Min/Hold Function l Display trend graph & Alarm l Display XYZ axis and vector l Display R, D, I values l S or N Polar indication | l Range: ±100μT and ±1000μT l DC Basic Accuracy: 0.25% l AC Basic Accuracy: 1% l Finest resolution: 0.1nT l DC/AC measurement mode switch l Frequency response: DC- 1kHz l Smart record and review l [GF603S] Real-time spectrum analysis |
GUI Operation System
With the handheld instrument operating system (GUI Operation System) developed by COLIY, it’s very efficient and convenient for operators to choose menu by touching, to operate magnetometer. | |
Display Style
Color LCD shows magnificent data: time, value, polarity, Max, Min, note, Alarm, XYZ axis and vector of Magnetic Flux Density, Declination/Inclination (D/I), and trend graph. | |
Smart Record and Review
Detailed record list, operators can use MEMO to memorize any specification of every measurement. Click any record list, operators can review all the information recorded as screen shots and add note to every item. | |
XYZ Display Mode
GF603 has many display modes to be chosen: Standard Mode, XYZ Mode, D/I Mode, Graph Mode, Polarity Mode and Spectrum Mode. And XYZ Mode shows vector value, XYZ component values and alarm value. | |
D/I Display Mode
Declination is the angle that between the X axis and the projection of the field vector onto the XY plane. Inclination is the angle that between the field vector and the XY plane. And D/I Mode shows Resultant (vector value, R), Declination (D) and Inclination (I) values. | |
Real-time Spectrum Analysis
GF603S has the function of real-time spectrum analysis within the frequency range 15Hz- 1kHz. | |
AC Measurement Mode
GF603 can be used to detect DC magnetic field in DC measurement mode and AC magnetic field in AC measurement mode respectively, and the frequency response range is DC~ 1kHz. | |
Magnetic Pole DIirection
GF603 could show the clear polar indication by a colorful and dynamic cartoon picture. Picture in the left is adopted from Polar Mode displayed in the LCD screen during operation. | |
3D Movement Platform
3-Direction Precision Movement Platform, is made of non-magnetic material. Users fixed the probe on the bracket front-end, and then manually rotate the knob so that the probe moves stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum stroke of each axis is 150mm, and positioning accuracy is 0.1mm. |
SMART computer software has up to 7 digital readouts, and it has rich features: Automatically record and display trend graph; Display XYZ axis and vector of magnetic flux density, maximum and minimum in real time; Export saved data from the gaussmeter host; Record and save measurement data in real time.
Model | GF603 / GF603S | ||||||
(DC) Measurement Specification | |||||||
Tested item | X, Y, Z | Vector R | *D | *I | |||
Range (FS) | ±100μT | ±1000μT | 173μT | 1732μT | ±180° | ±90° | |
Accuracy | ±0.25% Reading ± 0.1% FS | ±0.25% Reading ± 0.1% FS | ±0.5% Reading ± 0.1% FS | ±0.5% Reading ± 0.1% FS | 1° | 1° | |
Finest Display Resolution | 0.1nT | 0.1nT | 0.1° | 0.1° | |||
Measurement Resolution | <1nT | <10nT | <1nT | <10nT | 0.1° | 0.1° | |
[Probes without Temp. Compensation] Typical Temperature Coefficient ppm/℃ | ±100 | ±200 | ±100 | ±200 | N/A | ||
[Probes with Temp. Compensation] Typical Temperature Coefficient ppm/℃ | ±25 | ±50 | ±25 | ±50 | N/A | ||
Display Digits | 5 digits (More display digits will be shown in supporting PC software) | 4 digits | |||||
Real-time Spectrum | Only GF603S | N/A | |||||
Hysteresis | <2nT for exposure to up to 2 x full scale | N/A | |||||
(AC) Measurement Specification | |||||||
*Range | X, Y, Z | ±70μT | ±700μT | ||||
R | 121.2μT | 1212.4μT | |||||
Accuracy | X, Y, Z | ±1% Reading ± 0.1% FS [fT ≤ 300Hz] ±2% Reading ± 0.1% FS [300Hz < fT ≤ 500Hz] ±10% Reading ± 0.1% FS [500Hz < fT ≤ 1000Hz] | |||||
R | ±2% Reading ± 0.1% FS [fT ≤ 300Hz] ±4% Reading ± 0.1% FS [300Hz < fT ≤ 500Hz] ±18% Reading ± 0.1% FS [500Hz < fT ≤ 1000Hz] | ||||||
Frequency Response [fT] | DC – 1kHz | ||||||
Front Panel | |||||||
Screen | 3.2 inches color resistive touch LCD,320x240 Pixel | ||||||
Units | Gauss(G), Tesla(T), Amperes per meter (A/m) | ||||||
Display Update Rate | 3 readings/second | ||||||
Display Mode | DC, AC, XYZ Axis, Vector R, Declination, Inclination, MAX, MIN, Trend Graph, Alarm, Polarity Indication, Real-time Spectrum [GF603S] etc. | ||||||
Probe | |||||||
Start-up Time | 150 ms | ||||||
Warm-up Time | 15 min | ||||||
Probes | See "Probe Specifications" for details. | ||||||
Probe Cable Length | Standard 1.5m; Customizable longest length of 30 m | ||||||
USB Interface | |||||||
Function | 1, Communication Interface: to connect PC with gaussmeter host for monitoring the measurement; 2, Charging interface: to connect PC or mobile power with gaussmeter host for charging | ||||||
Software/ Driver | SMART PC Software without any driver | ||||||
Host Specifications | |||||||
Operating Temperature | +15℃ to +35℃(Rated Accuracy) -10℃ to +60℃(Reduced accuracy) | ||||||
Storage Temperature | - 20°C to +75°C | ||||||
Ambient Magnetic Field | <100G (10mT) | ||||||
Battery | Rechargeable 4500mAH Li-ion | ||||||
Operating Battery Life | 5 hours; Can be charged by AC power or portable battery | ||||||
Dimension | 238 mm W × 95 mm H × 42 mm D | ||||||
Weight | 350g | ||||||
Certification | CE Certification, EMC Certification |
Note:
1, D- Declination, is the angle that between the X axis and the projection of the field vector onto the XY plane.
2, I- Inclination, is the angle that between the field vector and the XY plane.
3, AC Range mentioned above refers to AC magnetic field measurement range after DC magnetic field is shielded, so if DC magnetic field is not shielded, and users want to measure magnetic field in AC measurement mode, AC Range is equivalent to the value that 0.7 times of DC Range minus DC magnetic field intensity. [SQRT(2)/2 ≈ 0.7]
Model GF603 Magnetometer Probes | |||||
Probe Model | *Range | Frequency Response | Typical Temperature Coefficient | DC Accuracy ( 25℃) | Stem Material |
GF-Y01 | ±100μT | DC-1kHz | ±100ppm/℃ | ±0.25% | POM |
GF-Y01T | ±100μT | DC-1kHz | ±25ppm/℃ | ±0.25% | POM |
GF-Y10 | ±1,000μT | DC-1kHz | ±200ppm/℃ | ±0.25% | POM |
GF-Y10T | ±1,000μT | DC-1kHz | ±50ppm/℃ | ±0.25% | POM |
Note:
1, Three-axis fluxgate probe can be customized within ±10G; Unit Conversion: 1G=100,000nT;
2, Fluxgate probe’s dimension: 107 x 32 x 32mm, and its operating temperature: -20℃ to +60℃;
3, Fluxgate probe’s environmental protection / sealing is IP66 by default;
4, Please contact Coliy for probes with higher environmental protection, the fluxgate probe in the long-term work of 50 meters underwater.
Model | Descriptions |
GHOLD100 | 3-Direction Precision Movement Platform, is made of non-magnetic material. Users fixed the probe on the bracket front-end, and then manually rotate the knob so that the probe moves stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum stroke of each axis is 150mm, positioning accuracy of 0.1mm; center load: 10kg; weight: 3.5kg |
SAMRT PC Software | PC SOFTWARE for Magnetometer |
Probe Extension Cable | MAX length is 30m |
The most popular configuration |
Package Product No. GF60301: Magnetometer GF603 + Probe GF-Y01 |
Package Product No. GF60310: Magnetometer GF603 + Probe GF-Y10 |
Package Product No. GF603S01: Magnetometer GF603S + Probe GF-Y01 |
Package Product No. GF603S10: Magnetometer GF603S + Probe GF-Y10 |
Description of Magnetometer Host Type Selection
Magnetometer | Description |
GF603 | Magnetometer WITHOUT the function of real-time spectrum analysis |
GF603S | Magnetometer WITH the function of real-time spectrum analysis |
Description of Probe Type Selection
GF | Y | 01 | T |
PROBE PRINCIPLE
GF- Fluxgate Probe
| PROBE TYPE
Y- Three-axis Probe T- Transverse Probe A- Axial Probe … | MEASUREMENT RANGE
01- Range of 1G/Axis 10- Range of 10G/Axis | TEMPERATURE COMPENSATION
BLANK- Without T- With |
Coliy GF603 3-Axis Fluxgate Magnetometer.pdf
Coliy GF603 CE CERTIFICATE OF CONFORMITY
Coliy GF603 GAUSSMETER EMC TEST REPORT