Descrition:BENEFIT RATING: ★★★★★
Ray | Model | Sensor | Range |
Gamma ray sensitivity (Cs137,1µSv/h) |
Characteristic |
Portable | |||||
α、β | R900 | ZnS+Plastic scintillator | 1Mcps | Active area:170cm² | |
R700 (Probe CS30D) |
ZnS+Plastic scintillator | 1Mcps | Active area :30cm² | ||
α、β、γ | R800 | Φ35×35mmPIPS | 10mSv/h | 40cps |
Recognize α β γ Χ Ray category α energy spectrum
analysis High detection efficiency |
R500 | Geiger tube | 1mSv/h | 7cps |
Large window Geiger tube Unable to distinguish between rays category |
|
910 | Geiger tube | 1mSv/h | 2cps | Small window Geiger tube Unable to distinguish between rays category | |
γ | RS10 | CZT | 10mSv/h | 60cps |
Energy spectrum analysis , resolution
<1.5%@662kev(Cs137) |
Φ50x50mm NaI crystal | 1mSv/h | 800cps |
Energy spectrum analysis , resolution
<8%@662kev(Cs137) |
||
R750 |
Φ80x80mm Plastic scintillator |
0.2mSv/h | 2000cps |
Super-high sensitivity
Background value removal
Can detect low-energy x-rays
|
|
R700 (Probe CS75) |
Φ75x75mm Plastic scintillator | 0.2mSv/h | 1500cps | High sensitivity | |
R700 (Probe CS30A) |
φ30x30mm NaI crystal | 1mSv/h | 350cps | Response time:1sec | |
RM600 | Geiger tube | 1mSv/h | 7cps |
Solid metal shell
Water resistant 10 meters
|
|
RW10 | φ35x35mm NaI crystal | 1.5mSv/h | 500cps |
It can detect underwater X, gamma ray, underwater continuous work of 100 meters |
|
RH-200 | Resistance radiation scintillator detector | 200Sv/h |
Radiation resistant probe
Optional range:1Sv/h、10Sv/h、 50Sv/h、 100Sv/h 、200Sv/h |
||
RC510 | CdTe | 10mSv/h | 500cps |
New aperture imaging sensor
Gamma ray image
resolution1024×768
View angle 60°
|
|
Neutron,γ | N10 | 10 * 10 * 10 (mm3) Coliy patented H type sensor | 10mSv/h(n) 20mSv/h(γ) | 0.5cps(252Cf ) |
4π omnibearing
γ suppression
ratio:≥1000:1 |
N20 | 20 *20 *20 (mm3) Coliy patented H type sensor | 10mSv/h(n) 10mSv/h(γ) | 2.7cps(252Cf ) | ||
Wall-hung Type Model R2000 | |||||
α、β | CS30D |
ZnS+ Plastic scintillator |
1Mcps | Active area:30cm² | |
γ |
CS75 |
Φ75x75mm Plastic scintillator |
0.2mSv/h | 1500cps | High sensitivity |
CS10 |
CZT | 10mSv/h | 60cps |
Energy spectrum analysis, resolution
<1.5%@662kev(Cs137) |
|
Φ50x50mm NaI crystal | 1mSv/h | 800cps |
Energy spectrum analysis, resolution
<8%@662kev(Cs137) |
||
RW10 | φ35x35mm NaI crystal | 1.5mSv/h | 500cps | It can detect underwater X, gamma ray, underwater continuous work of 100 meters | |
RH-200 | Resistance radiation scintillator detector | 200Sv/h |
Radiation resistant probe Optional range:1Sv/h、10Sv/h、 50Sv/h、 100Sv/h 、200Sv/h |
||
Neutron,γ | N10 | 10 * 10 * 10 (mm3) Coliy patented H type sensor | 10mSv/h(n) 20mSv/h(γ) | 0.5cps(252Cf ) |
4π omnibearing γ suppression ratio: ≥1000:1 |
N20 | 20 *20 *20 (mm3) Coliy patented H type sensor | 10mSv/h(n) 10mSv/h(γ) | 2.7cps(252Cf ) |
Equipment in stock will be shipped out in 5 work days after payment effected.