Your Location:Home > Gaussmeter

G91,G92 Handheld Gaussmeter

G91,G92 Handheld Gaussmeter Description:

• G91: Accuracy 2%, Range up to 30KG(3T)
• G91: Frequency response of DC- 10KHz
• G92: Accuracy 1%, Range up to 100KG(10T)
• G92: Frequency response of DC- 100KHz
• GUI Operation System
• S or N Polar indication
• Max/Min/Hold Function
• Smart record and review
• Display trend graph & Alarm
  Detail>>

G93 Handheld 3-Axis Gaussmeter

G93 Handheld 3-Axis Gaussmeter Description:

• Measurement range spans 109
• Range from 10nT(0.1mG) to 30T(300KG)
• Accuracy: 1% of reading
• Frequency response: DC to 1KHz
• High orthogonality accuracy (< 0.05°)
• High spatial resolution(0.1*0.1*0.1mm)
• Display trend graph & Alarm
• Display XYZ components and vector

Detail>>

G201 Desktop Gaussmeter

G201 Desktop Gaussmeter Description:

• Measurement range up to 60KG(6T)
• Best resolution up to 0.1G(0.01mT)
• Accuracy : 0.2% of reading
• Frequency response: DC to 20KHz
• S or N Polar indication
• Max/Min/Hold Function
• Smart record and review
• Display trend graph & Alarm
Detail>>

GMR50 Low-intensity Magnetic Field Gaussmeter

GMR50 Low-intensity Magnetic Field Gaussmeter Description:

• Range from 0.01μT to 4.5mT
• Accuracy: 1% of reading
• Frequency response: DC to 100Hz
• Full 5 display digits
• Smart record and review
• Max/Min/Hold Function
• Display trend graph & Alarm
• S or N Polar indication
Detail>>

GF603 Three-Axis Fluxgate Magnetometer

GF603 Three-Axis Fluxgate Magnetometer Description:

• Range: ±100μT, ±500μT and ±1000μT
• DC Basic Accuracy: 0.5% of reading
• AC Basic Accuracy: 1% of reading
• Finest resolution: 0.1nT
• DC/AC measurement mode switch
• Frequency response: DC- 1KHz
• Stability: ±1nT/Axis (8 hours, 25 ℃)
• Display trend graph & Alarm
• Display XYZ components and vector
Detail>>

GFP703 3-Axis Fluxgate Magnetic Field Transmitter

GFP703 3-Axis Fluxgate Magnetic Field Transmitter Description:

• High-precision Digital Output (RS485)
• High Resolution: up to 0.1nT
• Wide Supply Power: 5 to 36VDC
• Range: ±100μT, ±500μT and ±1000μT
• DC basic accuracy: 0.5% of reading
• AC basic accuracy: 1% of reading

Detail>>

FDU101 Fluxgate Sensor Data Acquisition Unit

FDU101 Fluxgate Sensor Data Acquisition Unit Description:

• Digitizes a 3-Axis Fluxgate Sensor
• Sample rate: up to 300ksps (24 bits ADC)
• Digital signal output (RS485)
• Accuracy: 0.01%
• Resolution: 0.01nT(0.1μG)
• Power supply: ±15VDC
• Compatible with most Bartington fluxgate sensor

Detail>>

FDU108 Fluxgate Sensor Data Acquisition Unit

FDU108 Fluxgate Sensor Data Acquisition Unit Description:

• Digitizes up to 16 3-axis fluxgate sensors
• Sample rate: up to 300ksps (24 bits ADC)
• Digital signal output (RS485)
• Accuracy: 0.01%
• Resolution: 0.01nT(0.1μG)
• Power supply: 100- 240VAC
• Multiple sensors synchronous display
• Compatible with most Bartington fluxgate sensor

Detail>>